10 Crestway, Tarleton - GB-Preston PR4 6BE - UK
+44 (0)1494 465 166
Follow us:

    RSV

    The exodraft chimney fan RSV is an exhaust fan built with a strong vertical discharge.

    As the chimney fan is mounted on top of the chimney, a vacuum is created in the flue pipe and the chimney. The chimney fan can be used for all types of fuels but is particularly suitable for solid fuel boilers, fireplaces and stoves.RSV_web_wide

    The chimney fan is part of an exodraft system and must be connected to an exodraft control. See below for matching accessories.

    Design

    exodraft RSV chimney fans are designed so that they can withstand temperatures up to 250 ° C while maintaining continuous operation. The chimney fan is made of cast aluminium; all screws and bolts are made of stainless steel.

    The chimney fans RSV009, RSV012, RSV014 and RSV016 are equipped with a stainless steel axial impeller.

    The chimney fans RSV250, 315 and 400 are equipped with a centrifugal impeller made of cast aluminium and are typically used for larger systems where multiple fireplaces are connected to the same chimney.

    The motor is an enclosed heat-resistant asynchronous motor with permanently lubricated ball bearings, which is protected from the flue gas.

    A special cooling vane wheel and cooling air slots safely ensure continuous cooling of the motor.

    The cable is heat resistant and strain relieved and protected by a reinforced hose casing.

    All of these combined give the chimney fan high operational reliability and a long service life.

    The chimney fan is hinged, which means the chimney sweep has easy access to sweep the chimney.

    A protective stainless steel grille is mounted to prevent contact and stop birds from entering the chimney.

     Rev / min.VoltageAmpkWWeight
    RSV00914001 x 230 V0.14 A0.0513 kg
    RSV0121400 1 x 230 V 0.35 A 0.13 17 kg
    RSV0141400 1 x 230 V 0.8 A 0.16 24 kg
    RSV0161400 1 x 230 V 1.8 A 0.32 35 kg
    RSV16014001 x 230 V0.14 A0.0413 kg
    RSV20014001 x 230 V0.35 A0.0718 kg
    RSV25014001 x 230 V0.8 A0.1627 kg
    RSV31514001 x 230 V1.8 A0.3737 kg
    RSV40014001 x 230 V2.6 A0.3747 kg
    RSV400**17203 x 230 V4.0 A0.7552 kg
    RSV450**17203 x 230 V6.5 A1.558 kg
       Download Full Data Sheet

    ** Motor factory wired in triangle 3×230 V, but can be wired in star for direct use on 3×400 V supply

    RSV009-4-1
    Square chimney fan with vertical discharge. Capacity up to 370 m³/hr. Single poled motor and with axial wing.
    RSV012-4-1
    Square chimney fan with vertical discharge. Capacity up to 740 m³/hr. One poled motor and with axial wing.
    RSV014-4-1
    Square chimney fan with vertical discharge. Capacity up to 1,400 m³/hr. One poled motor and with axial wing.
    RSV016-4-1
    Square chimney fan with vertical discharge. Capacity up to 2,350 m³/hr. One poled motor and with axial wing.
    RSV160-4-1
    Square chimney fan. Capacity up to 500 m³/hr. One poled motor and with centrifugal impeller with vertical discharge.
    RSV200-4-1
    Square chimney fan with vertical discharge. Capacity up to 1,100 m³/hr. One poled motor and with centrifugal impeller.
    RSV250-4-1
    Square chimney fan with vertical discharge. Capacity up to 1,500 m³/hr. One poled motor and with centrifugal impeller.
    RSV315-4-1
    Square chimney fan with vertical discharge. Capacity up to 3,000 m³/hr. One poled motor and with centrifugal impeller.
    RSV400-4-1
    Square chimney fan with vertical discharge. Capacity up to 4,400 m³/hr. One poled motor and with centrifugal impeller.
    RSV400-4-2
    Square chimney fan with vertical discharge. Capacity up to 4,800 m³/hr. Three poled motor and with centrifugal impeller.
    RSV450-4-2
    Square chimney fan with vertical discharge. Capacity up to 7,300 m³/hr. Three poled motor and with centrifugal impeller.
    EFC15

    The EFC15 is a continuously variable electronic speed control for manual operation of exodraft chimney fans.

    Frequency converters

    Frequency converter FRK008 for the exodraft chimney fan RSV400-4-2 and frequency converter FRK009 for the exodraft chimney fan RSV450-4-2

    EFC16

    The EFC16 is a continuously variable electronic speed control for manual operation of exodraft chimney fans

    EFC18

    The EFC18 control is an electronic 9-speed control with an integrated automatic start/stop and boost function for the exodraft chimney fans

    EW41

    The EW41 is an automatic remote controlled control for exodraft chimney fans. It has an automatic temperature control, a signal to refuel, a boost function and an automatic stop function

    EBC20/22

    The EBC20 / 22 is an automatic control for exodraft chimney fans on boilers and large systems

    Rainshield

    Rainshield for the exodraft RSV009 and RSV160 chimney fans

    Flanges

    The exodraft flange system is used to mount the exodraft chimney fan on to steel chimneys

    Posted by bech_morten / Posted on 04 Jan
  • Post Comments 0